AGRICULTURE SPRAY PUMP BATTERY CHARGER


These battery chargers are specially designed for Spray Pump Battery Charger taking specific requirements into consideration.These based on SMPS technology adopting latest Pulse Width Modulation technique.

    Various available ranges are as follows
  • 12 volts , 0.7 Amps: Suitable for Single Battery up to 7.5 Ah capacity
  • 12 Volts, 1.7 Amps: Suitable for Single Battery up to 26 Ah capacityy

Other Non-standard ranges like 24 Volts, Suitable for Two Batteries in Sets also can be made available against specific request.

THE COMPANY :

Company with more than 20 years of Experience in switching power supplies and charger
Manufactured in a state - of - the - art ISO – 9001:2015 Facility.
Highly qualified & experienced R&D team.


Technical Specifications 12V, 0.7A 12V, 1.7A
Electrical Characteristics
Input Voltage 150 – 270V AC 150 – 270V AC
Output Voltage-Boost mode 14.4V DC 14.4V DC
Output Voltage-Float mode 13.8V DC 13.8V DC
Charging Current-Boost mode 0.7A 1.7A
Leakage Current @ 230 V ac < 2mA < 2mA
Line regulation < 1% < 1%
Load regulation < 1% < 1%
Ripple content 150mV p-p 150mV p-p
Dielectric strength:
Between Input & Output 2kV AC 2kV AC
Between Input & Earth 1.5kV AC 1.5kV AC
Between Output & Earth 1.5kV AC 1.5kV AC
Protections
In rush current Limited by NTC Thermistor
Over voltage at Input Shut down above 300V AC
Under voltage at Input Cutoff at 140V AC. Cut in at 160V AC
Over voltage at Output 29.5V 15.5V
Short circuit at Output Protected Protected
Overload at Output Protected Protected
Reverse polarity of Battery Protected Protected
Other Features
Indications Boost/ Float mode-Dual Colour LED
Mechanical
Type of mounting Double Top mounting Type
Dimensions LxWxH 122x54x36 122x54x36
Environmental
Operating Temperature 0 – 50 Deg.C
Operating Relative Humidity 0 – 80% Max.
Vibrations 10 – 500Hz 2G-10min. / 1 Cycle 60 min. along all three axes

* Specification Can be changed without notice